Paper trail
Source notes
80 products are in the catalog. We only show a spec when the maker publishes it. Here's what's missing and where sources disagree.
What's missing
- Dometic CFX3 35
- Dometic doesn't list the inside temperature range for this model.
- Dometic doesn't list noise for this model.
- Dometic CFX3 45
- Dometic doesn't list the outside temperature range for this model.
- Dometic doesn't list noise for this model. The manual covers several models together, so we left that number out.
- Dometic CFX3 55IM
- Dometic doesn't give a separate average for the hours the ice maker is running.
- Dometic CFX3 75DZ
- Dometic doesn't list how the space is split between the two zones.
- Dometic doesn't list the temperature range for this model.
- ARB Zero 47 Quart
- ARB lists 0.8 Ah without saying per hour. The planner treats it as the average draw per hour.
- ARB Zero 69L Dual Zone
- ARB lists 2.9 kWh without saying how long that covers, so we don't use it as a daily figure.
- EcoFlow DELTA 2
- EcoFlow doesn't list a usable watt-hour number separate from the 1,024 Wh capacity.
- Jackery Explorer 1000 v2
- Jackery lists the car port as 12 V at 10 A and doesn't give it a watt rating.
- Battle Born BB10012 100Ah
- Battle Born doesn't print a watt-hour capacity.
- Renogy Core 12.8V 100Ah
- Renogy doesn't print a watt-hour capacity for this battery.
- Renogy RNG-100D-SS 100W
- We left the cell count blank because Renogy's own pages don't agree.
- Goal Zero Boulder 100
- Goal Zero has a spot for the voltage at full power, but no number is filled in.
- Goal Zero doesn't list the current figures for this panel.
- Goal Zero doesn't list how efficient this panel is.
- Victron Orion-Tr Smart 12/12-30
- This charger doesn't take solar. It only charges from the alternator.
- REDARC BCDC1240D
- REDARC doesn't list how efficient this charger is.
- ARB Zero 38 Quart
- ARB lists 0.8 Ah without saying per hour, and doesn't say the outside or inside temperature for that test.
- ARB Zero 63 Quart
- ARB lists 0.8 Ah without saying per hour. The planner treats it as the average draw per hour.
- ARB Zero 73 Quart Dual Zone
- ARB lists 2.9 Ah without saying per hour. The planner treats it as the average draw per hour.
- ARB Zero 101 Quart Dual Zone
- ARB lists 3.1 Ah without saying per hour. The planner treats it as the average draw per hour.
- ARB doesn't list a USB output for this model.
- ARB Elements 63 Quart
- ARB doesn't say per hour, and doesn't give the outside or inside temperature for the test.
- ARB doesn't say how many cans this fridge holds.
- Dometic CFX3 25
- Dometic doesn't list noise for this model.
- Dometic CFX3 100
- Dometic doesn't list the inside temperature range for this model.
- Dometic CFX3 95DZ
- Dometic doesn't list how the space is split between the two zones.
- Dometic CFX5 25
- Dometic doesn't say how many cans this fridge holds.
- Dometic CFX5 35
- Dometic doesn't list the wall-power watts for this model.
- Dometic CFX5 55IM
- Dometic doesn't give a separate average for running with the ice maker off.
- Dometic CFX5 75DZ
- Dometic doesn't list an average for when both zones are set as a fridge.
- Dometic CFX2 28
- Dometic doesn't list an average 12 V draw per hour for this model.
- Dometic CFX2 37
- Dometic doesn't list an average 12 V draw per hour for this model.
- Dometic CFX2 45
- Dometic doesn't list an average 12 V draw per hour for this model.
- Dometic CFX2 57
- Dometic doesn't list an average 12 V draw per hour for this model.
- ICECO IPT20
- ICECO doesn't list a 24-hour energy figure for this model.
- ICECO doesn't say the supply voltage in the description we checked.
- ICECO GO20
- ICECO's manual doesn't say the outside or inside temperature for that 24-hour test.
- ICECO GOPACK12
- ICECO doesn't list a 24-hour energy figure on this page.
- ICECO doesn't list the full temperature range or the outside dimensions on this page.
- ICECO VL45PLUS
- ICECO's description doesn't list 24-hour energy, weight, size, supply voltage, or the full temperature range.
- ICECO APL20
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO APL35
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO APL55
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO JP40 Pro
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO JP50 Pro
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO JP Pro Dual Zone
- ICECO doesn't list 24-hour energy, weight, or size on this page.
- ICECO's title gives 40 and 51 quarts, but doesn't say how that splits between the two zones.
- ICECO VL35ProS
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO VL45ProS
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO VL60ProS
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO VL45
- ICECO doesn't give a clean weight or size for this model. A later table in the manual mixes it with another model, so we left those numbers out.
- ICECO VL60
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO VL75ProD
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO VL90ProD
- ICECO doesn't say the outside or inside temperature for that 24-hour test.
- ICECO BF65 / BF86
- ICECO doesn't list weight, size, or 24-hour energy separately for each size.
- ICECO doesn't say whether BF65 is the 66-quart or the 91-quart.
- Baratza Encore
- Baratza doesn't say how much energy one grind uses. Enter the minutes you actually grind.
- Cuisinart DCG-20N
- Cuisinart's US page doesn't list watts. A Cuisinart page in Colombia says 135 W and a shop says 130 W. We didn't use either.
- Instant Pot Duo 8QT
- Instant Pot doesn't list a startup surge or the energy for one meal.
- Ninja Air Fryer Pro XL
- Ninja's guide doesn't list weight, capacity, or the energy for one cook in the section we read.
- Ninja suggests a 3-minute preheat. That time is only counted if you include it in the minutes you enter.
- Duxtop 9100MC
- Duxtop doesn't list efficiency in the section we read.
- The plan uses the 1,800 W top setting. Duxtop doesn't publish a separate energy figure for a lower setting.
- Ninja Precision Temperature Kettle
- Ninja says one cup can boil in as little as 90 seconds. We don't assume that's how long you boil.
- Webasto Air Top Pro 25
- Webasto doesn't list a separate startup current. The plan uses the 21 W maximum for every hour you enter.
- Webasto lists 20 W maximum for gasoline. This entry uses the diesel figure, 21 W.
- Starlink Mini
- Starlink lists an average of 25–40 W, not one number. The plan uses 40 W, the top of that range.
- weBoost Drive Reach RV II
- weBoost lists 12 V at 1.8 A and doesn't print watts. 21.6 W is 12 times 1.8.
- Shurflo Revolution 4008
- Shurflo lists 7.5 A as the maximum and doesn't give a lower running wattage.
- Shurflo Revolution 4028
- Shurflo lists 5 A as the maximum and doesn't give a lower running wattage.
- Victron Phoenix 12/500
- The plan uses the 6 W draw with nothing plugged in, not the 1 W eco figure, unless you shorten the hours.
- ResMed AirSense 11 AutoSet
- ResMed's table lists these as watt-hours and doesn't say per hour. We treat them as one hour of therapy, because standby is 2 Wh and the note calls them measured power draw.
- ResMed doesn't list the draw through a 12 V converter. On wall power, inverter loss applies when you pick an inverter.
- ResMed AirMini
- ResMed doesn't say whether 6.3 Wh is from a wall outlet or a DC source, so we don't add inverter loss.
- ResMed doesn't list a humidifier draw for the AirMini.
- BLUETTI AC180
- BLUETTI doesn't list inverter efficiency or idle watts, so we don't add them on top of AC loads.
- Anker SOLIX C1000
- Anker's support article doesn't say how many cycles this battery is rated for.
- Anker doesn't list inverter efficiency here.
- Jackery SolarSaga 100
- Jackery also prints 104 W ± 5 W under a brighter rear-light test. The plan uses the standard 100 W rating.
- LightLeaf 140W hatch panel
- Neither Escapod nor LightLeaf prints the panel's voltage and current figures.
- Nobody publishes how much a simpler charge controller gives up compared with a better one. The plan uses the sun hours and efficiency you enter, and doesn't assume a controller loss.
- LightLeaf 190W hatch panel
- Escapod's Voyager page doesn't list voltage, current, or the type of charge controller.
- Dometic CoolAir RTX 1000 12V
- Dometic doesn't list separate currents for Eco, Boost, Auto, or Manual.
- Some shops quote about 18–19.5 A in Eco mode. Dometic doesn't, so we don't use that number.
- The plan uses 12 V times the amps and hours you enter. The 570 W on the data plate is the rated input, not the current you set.
- Dometic CoolAir RTX 2000 12V
- Dometic doesn't list separate currents for Eco, Boost, Auto, or Manual on this page.
- The plan uses 12 V times the amps and hours you enter. The 650 W on the data plate is the rated input, not the current you set.
- Dometic CoolAir RTX 2000
- Dometic doesn't say how big a battery this cooler needs.
- Dometic says 19 A in the description and 8 A in a highlight on the same page, so we don't pick one Eco current.
Where sources disagree
- Dometic CFX3 75DZ · Product description volume
We used: 75 L total volume (IEC 62552-3)
We left out: The same page’s short description says 74 L
- ARB Zero 47 Quart · Weight
We used: 52.6 lb on the current ARB USA store page
We left out: 47.6 lb in the Zero product release
- EcoFlow DELTA 2 · X-Boost
We used: 2200 W in the user manual
We left out: Some regional EcoFlow pages say 2400 W
- EcoFlow RIVER 2 Pro · Weight
We used: Approximately 7.8 kg (17.2 lb) in the user manual
We left out: The US product page says approximately 18.2 lb
- Goal Zero Yeti 500X · Pack capacity
We used: 497 Wh on the current product page
We left out: User guide says up to 505 Wh (10.8 V, up to 46.8 Ah)
- Renogy Core 12.8V 100Ah · Capacity
We used: 100 Ah, the rated capacity Renogy prints
We left out: The manual introduction also says 106 Ah instead of 100 Ah
- Renogy RNG-100D-SS 100W · Cell count
We used: Not shown
We left out: This datasheet says 36 cells. A Renogy EU listing for the black-frame 100 W panel says 32 cells.
- Renogy 40A DC-DC with MPPT · Nominal output power
We used: 616 W in the US manual and US product page
We left out: The UK product page lists 584 W
- Renogy 40A DC-DC with MPPT · Solar input voltage
We used: 13–30 V DC in the January 2026 US manual
We left out: The US product page lists 10–30 V DC
- ARB Zero 63 Quart · Weight
We used: 61.7 lb on the current ARB USA store page
We left out: 54.2 lb in the Zero product release
- ARB Zero 73 Quart Dual Zone · Weight
We used: 68.3 lb on the current ARB USA store page
We left out: 62.4 lb in the Zero product release
- ARB Zero 101 Quart Dual Zone · Weight
We used: 80.7 lb on the current ARB USA store page
We left out: 72.5 lb in the Zero product release
- Dometic CFX3 25 · Can count
We used: 33 cans of 12 oz, from the spec list
We left out: The description also says the 25 L holds 40 cans
- Dometic CFX3 95DZ · Capacity wording
We used: 93 L total, from the spec list
We left out: A Dometic US promo page calls it a 94 L cooler
- Dometic CFX5 45 · Average 12V consumption
We used: 1.05 Ah/h and R1234yf on the US model we list
We left out: Another Dometic listing of this cooler shows 0.76 Ah/h and R600a
- Dometic CFX5 95DZ · Volume and can count
We used: 94 L and 121 cans, from the spec list
We left out: The same page’s feature list says 96 L and 133 cans
- Dometic CFX2 45 · Average consumption
We used: Not shown. The US page doesn't print an average draw.
We left out: Another Dometic listing shows 0.86 Ah/h and uses R600a
- ICECO JP50 Pro · Capacity
We used: 50 qt in the ICECO manual catalog
We left out: The US product title says 51 qt
- ICECO VL60 · 24-hour consumption
We used: 0.416 kWh in the manual's main test
We left out: A later table in the same manual pairs this cooler with 0.545 and 0.562 kWh, which doesn't match the main test
- ICECO VL75ProD · Capacity
We used: 79 qt in the ICECO manual catalog
We left out: The US product title says 79.2 qt
- Expion360 VPR 4EVER 120Ah · Weight
We used: 30 lb
We left out: 30.8 lb
- Expion360 VPR 4EVER 120Ah · Dimensions
We used: 11.9 × 6.8 × 8.6 in
We left out: 11.93 × 6.81 × 8.82 in
- Expion360 VPR 4EVER 100Ah · Capacity
We used: 102 Ah
We left out: 100 Ah
- Expion360 VPR 4EVER 100Ah · Capacity
We used: 102 Ah
We left out: 100 amp hour
- Expion360 VPR 4EVER 100Ah · Weight
We used: 29 lb
We left out: 29.3 lb
- Expion360 VPR 4EVER 100Ah · Dimensions
We used: 11.9 × 6.8 × 8.6 in
We left out: 11.93 × 6.81 × 8.82 in
- Dometic CoolAir RTX 1000 12V · Cooling capacity
We used: Up to 1100 W, ISO 5151
We left out: 1200 W
- Dometic CoolAir RTX 1000 12V · Weight
We used: 23 kg
We left out: Approximately 24 kg (52.8 lb)
- Dometic CoolAir RTX 2000 12V · Cooling capacity
We used: Up to 1700 W, ISO 5151
We left out: 2000 W
- Dometic CoolAir RTX 2000 12V · Maximum cooling current
We used: 30 A
We left out: 58 A
- Dometic CoolAir RTX 2000 12V · Weight
We used: 32 kg
We left out: Approximately 33 kg (72.6 lb)
- Dometic CoolAir RTX 2000 · Eco current
We used: Not used
We left out: 19 A in the description
- Dometic CoolAir RTX 2000 · Eco current
We used: Not used
We left out: 8 A in a page highlight