Renogy 40A DC-DC with MPPT
RBC40D1S-G1
A 40 A charger that can take the alternator or a solar array. The plan uses the 616 W nominal output while you are driving. Solar through this unit is not added on top, because the manual’s solar limits are a separate input.
| Spec | Published | Source |
|---|---|---|
| Maximum charging current | 40 A | Renogy RBC40D1S-G1 user manual |
| Nominal output power | 616 W | Renogy RBC40D1S-G1 user manual |
| Max charging efficiency | 93% | Renogy RBC40D1S-G1 user manual |
| Steady conversion efficiency | Greater than 92% | Renogy RBC40D1S-G1 user manual |
| Solar input voltage | 13–30 V DC | Renogy RBC40D1S-G1 user manual |
| Maximum solar input power | 670 W | Renogy RBC40D1S-G1 user manual |
| Maximum solar input current | 45 A ± 5% | Renogy RBC40D1S-G1 user manual |
| Start-battery voltage | 7–16 V DC | Renogy RBC40D1S-G1 user manual |
| Alternator input, product page | 13.2–16.0 V traditional, 12–16.0 V smart | Renogy 40A DC-DC with MPPT product page |
| Weight | 1.2 kg (2.65 lb) | Renogy RBC40D1S-G1 user manual |
| Dimensions | 195 × 149 × 48 mm | Renogy RBC40D1S-G1 user manual |
| Battery types | Sealed/AGM, GEL, flooded, LiFePO4 | Renogy RBC40D1S-G1 user manual |
| Enclosure | IP31 | Renogy RBC40D1S-G1 user manual |
Figures that disagreed
Nominal output power
We used: 616 W in the US manual and US product page Renogy RBC40D1S-G1 user manual
We left out: The UK product page lists 584 W Renogy UK, 40A DC-DC with MPPT
Solar input voltage
We used: 13–30 V DC in the January 2026 US manual Renogy RBC40D1S-G1 user manual
We left out: The US product page lists 10–30 V DC Renogy 40A DC-DC with MPPT product page