Current 12 V RTX 2000. DC only, so no inverter. The amp field starts at the published 10 A minimum and stops at 30 A. Hours are yours. Eco current is not on this page.

Sourced specifications
SpecPublishedSource
Input voltage12 V DCDometic CoolAir RTX 2000 12V product page
Operating voltage10–15 VDometic RTX 1000/2000 installation manual
Cooling current10–30 ADometic CoolAir RTX 2000 12V product page
Cooling capacityUp to 1700 W, ISO 5151Dometic CoolAir RTX 2000 12V product page
Rated power input650 WRTX 2000 data plateDometic RTX 1000/2000 installation manual
Operating temperature5–52°CDometic CoolAir RTX 2000 12V product page
Battery180 Ah or greaterDometic RTX 1000/2000 installation manual
Weight32 kg (70.56 lb)Dometic CoolAir RTX 2000 12V product page
Dimensions860 × 308 × 645 mm (W × H × D)Dometic CoolAir RTX 2000 12V product page