Victron Phoenix 12/500
12/500 VE.Direct
12 V pure sine inverter. AC loads in the plan are divided by its 90% efficiency, and idle watts apply for the hours you say it stays on.
| Spec | Published | Source |
|---|---|---|
| Continuous power at 25°C | 500 VA / 400 W | Victron Phoenix VE.Direct inverter datasheet |
| Continuous power at 40°C | 350 W | Victron Phoenix VE.Direct inverter datasheet |
| Peak power | 900 W | Victron Phoenix VE.Direct inverter datasheet |
| Maximum efficiency | 90%12 V model | Victron Phoenix VE.Direct inverter datasheet |
| Zero-load power | 6 W12 V model | Victron Phoenix VE.Direct inverter datasheet |
| ECO-mode zero load | 1 W12 V model | Victron Phoenix VE.Direct inverter datasheet |
What's missing
- The plan uses the 6 W draw with nothing plugged in, not the 1 W eco figure, unless you shorten the hours.