Why a 100 W panel is an STC nameplate, and how sun hours and system losses decide whether it covers the fridge.

Nameplate watts are a lab number

Renogy’s RNG-100D-SS datasheet rates the panel at 100 W under standard test conditions: 1,000 W/m², 25°C cell temperature, air mass 1.5. A roof panel in the afternoon is hotter than 25°C, rarely square to the sun, and sometimes partly shaded by a roof rack. It will not deliver 100 W for five clock hours.

The planner keeps the 100 W as the sourced spec and puts the messy part in two sliders you control: peak sun hours, and a system efficiency that stands in for angle, heat, wiring, and the charge controller. The default is 5 hours and 75%. Both are assumptions. They are labeled that way, and they ride along in the share link so a reader can see them.

A fridge-sized example

One 100 W panel at 5 peak sun hours and 75% efficiency is 100 × 5 × 0.75 = 375 Wh in a day. The CFX3 45 at its published hot-day test is about 297 Wh before any other load. On that exact day the panel covers the fridge and not much else.

Add a fan and the panel falls short. A second 100 W panel, or the 200 W RSP200D, closes the gap. Moving the ambient slider up increases the fridge faster than the panel, because the panel estimate does not know your weather. If the sky is hazy, lower the sun hours rather than editing the panel’s nameplate.

Goal Zero’s Boulder 100 is also a 100 W panel, with a published 22.5 V open-circuit voltage and an 8 mm port. Vmp and Imp are not on the current product page, so those cells stay empty. You can still plan with the 100 W rating.

The panel does not charge the fridge directly

Dometic’s CFX FAQ says to pair a panel around 100 W or larger with a battery, because the cooler wants a steady DC voltage and the panel’s voltage moves all day. A power station with a published solar input does that job in one box. The DELTA 2 manual allows 11–60 V and up to 500 W. The Yeti 500X user guide allows 13–22 V and 120 W on the 8 mm port. A panel outside that window is the wrong panel, even if the wattage looks fine.

Match Voc, cold, to the station’s maximum input voltage before you trust the watt-hour estimate. This site does not calculate cold-weather Voc rise. The temperature coefficient is on the Renogy datasheets if you want to do that sum yourself.